CR5 register
SMPSLVL | SMPSLVL[3:0] SMPS Output Level Voltage Selection Select the SMPS output voltage with a granularity of 50mV. Default = ‘0100’ (1.4V) Vout = 1.2 + 0.05*SMPSOUT (V) |
SMPSBOMSEL | SMPSBOMSEL: SMPS BOM Selection:
|
SMPS_BOF_STATIC | SMPS_BOF_STATIC: SMPS Bypass on the Fly static
|
NOSMPS_BOF | NOSMPS_BOF: No SMPS Mode to be used in accordance to SMPS_BOF_STATIC =1 When this bit is set, the SMPS regulator will be disabled. Note that this configuration should be used only SMPS_BOF_STATIC=1.
|
SMPSLPOPEN | SMPSLPOPEN: In Low Power mode SMPS is in OPEN mode (instead of PRECHARGE mode). When this bit is set, when the chip is in Low power mode the SMPS regulator will be disabled (HZ) Documentation needed.
|
SMPSFBYP | SMPSFB Force SMPS Regulator in bypass mode When this bit is set, the SMPS regulator will be forced to operate in precharge mode. the actual state of SMPS can be observed thanks to the replica SR2.SMPSBYPR.
|
NOSMPS | NOSMPS: No SMPS Mode When this bit is set, the SMPS regulator will be disabled. Note that this configuration should be used only when SMPS_FB pad is directly connected to VBATT or Vext, without L/C BOM.
|
SMPS_ENA_DCM | SMPS_ENA_DCM: enable discontinuous conduction mode
|
CLKDETR_DISABLE | CLKDETR_DISABLE: disable SMPS clock detection The SMPS clock detection enables an automatic SMPS bypass switching in case of unwanted loss of SMPS clock.
|
SMPS_PRECH_CUR_SEL | SMPS_PRECH_CUR_SEL[1:0] Selection for SMPS PRECHARGE limit current
|
SMPS_BOF_DYN | SMPS_BOF_DYN: SMPS Bypass on the Fly dynamic
|